INPUT
Volt. 208Vac, 380Vac-480Vac
Three Phase Three Wire or Three Phase Four Wire + PE
Freq. 50Hz/60Hz
OUTPUT
Volt. 28VDC (20-32V adjustable)
Current rating: 300A,400A,500A,600A,800A,1000A,1200A...
Voltage regulation <1%
Ripple: <200mV
Voltage stability in line regulation: 0.5%
Voltage stability in load regulation: 0.5%
OTHERS
- Overall efficiency: 90%
- Standby losses: 50W (axial fan stopped)
- Protection: Input over voltage and under voltage, phase sequence error protection
- Output over voltage, under voltage, overload, and short circuit protection,overheating protection
- IP rating: IP54
- Noise:<65db
- Working under ambient temperature: -40℃-50℃
- MTBF: Inverter part:25,000 hours
- MTTR: less than 20mins
- Standard Reference:
- GJB 572A-2006
- MH/T 6018-2014
- ISO 6858: Aircraft Ground Support Electric Supplies.
- MIL-STD-704F Aircraft electric power characteristics
- Optional Spare: Cables 2×120mm² or 2×140mm² super flexible cables with Connector